e-series surface mount mixer 2110 ? 2170 mhz efm-2100 m/a-com inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. m/a-com makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does m/a-com assume any liability whatsoever arising out of the use or application of any product(s) or information. ? north america tel: 800.366.2266 / fax: 978.366.2266 ? europe tel: 44.1908.574.200 / fax: 44.1908.574.300 ? asia/pacific tel: 81.44.844.8296 / fax: 81.44.844.8298 visit www.macom.com for additional data sheets and product information. v2 1 features ? lo power +13 dbm ? +22db compression point ? surface mount ? +32dbm iip3 ? up and down converting ? tape and reel packaging available description m/a com's efm-2100 uses a novel, patent pending design to achieve very high linearity at low lo drive levels. typically ip3 performance is +32dbm with an lo drive level of just +13dbm. the mixer combines phemt devices and carefully matched transformers in a surface mount package which can be used for both up and down converting. it is ideally suited for wireless applications where high linearity is required. parts are packaged in tape & reel. ordering information part number package EFM-2100TR tape and reel (300 piece reel) sm - 106 - non hermetic package electrical specifications: t a = 25c, z 0 = 50 ? 1 parameter test conditions frequency units min typ max rf frequency dc bias 3v 0.3v 2110 -2170 mhz ? ? ? lo frequency dc bias 3v 0.3v 1650 - 2070 mhz ? ? ? if frequency dc bias 3v 0.3v 100 - 500 mhz ? ? ? conversion loss ? 2110 - 2170 db - 8.5 10.0 isolation lo to rf 1650 - 2070 db 10.0 16.0 ? isolation lo to if 1650 - 2070 db 20.0 25.0 ? isolation rf to if 2110 - 2170 db 25 35 ? vswr lo 1650 - 2070 ? ? 2.5 ? vswr rf 2110 - 2170 ? ? 2.8 ? 0.800 (20.32) 0.400 (10.16) 1 2 3 4 5 6 7 8 9 10 11 12 14 13 0.220 max (5.50) 0.100 (2.54) 0.100 (2.54) 0.070 (1.80) 0.083 (2.10) 0.100 (2.54) orientation dot 0.078 (2.00) 0.440 (11.16) 0.679 (17.24)
e-series surface mount mixer 2110 ? 2170 mhz efm-2100 m/a-com inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. m/a-com makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does m/a-com assume any liability whatsoever arising out of the use or application of any product(s) or information. ? north america tel: 800.366.2266 / fax: 978.366.2266 ? europe tel: 44.1908.574.200 / fax: 44.1908.574.300 ? asia/pacific tel: 81.44.844.8296 / fax: 81.44.844.8298 visit www.macom.com for additional data sheets and product information. v2 2 pin configuration pin no. function 1 ground 8 ground 2 rf 9 lo 3 ground 10 ground 4 ground 11 ground 5 ground 12 ground 6 ground 13 bias 7 ground 14 if absolute maximum ratings 1 1. operation of this device above any one of these parameters may cause permanent damage. parameter absolute maximum max rf power 200 mw peak if current 40 ma operating temperature -40c to +85c storage temperature -55c to +125c esd rating zero electrical specifications: t a = 25c, z 0 = 50 ? 1 parameter test conditions frequency units min typ max if vswr ? 100 - 500 ? ? 1.8 ? input ip3 up converting ? dbm 30.0 34.0 ? input 1db compression ? 1850 - 1980 dbm ? 22.0 ? input ip3 down converting ? dbm 30.0 34.0 ? schematic
e-series surface mount mixer 2110 ? 2170 mhz efm-2100 m/a-com inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. m/a-com makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does m/a-com assume any liability whatsoever arising out of the use or application of any product(s) or information. ? north america tel: 800.366.2266 / fax: 978.366.2266 ? europe tel: 44.1908.574.200 / fax: 44.1908.574.300 ? asia/pacific tel: 81.44.844.8296 / fax: 81.44.844.8298 visit www.macom.com for additional data sheets and product information. v2 3 lo - rf isolation lo?if isolation iip3 typical performance curves conversion loss 1 db compression point 20.0 22.0 24.0 26.0 28.0 1510 1622 1734 1846 1958 2070 freq (mhz) db -9 -8 -7 -6 -5 2010 2042 2074 2106 2138 2170 freq(mhz) db -26 -22 -18 -14 -10 1510 1622 1734 1846 1958 2070 freq (mhz) db -50 -45 -40 -35 -30 -25 1510 1622 1734 1846 1958 2070 freq (mhz) db 25 27 29 31 33 35 2010 2042 2074 2106 2138 2170 freq(mhz) db
e-series surface mount mixer 2110 ? 2170 mhz efm-2100 m/a-com inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. m/a-com makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does m/a-com assume any liability whatsoever arising out of the use or application of any product(s) or information. ? north america tel: 800.366.2266 / fax: 978.366.2266 ? europe tel: 44.1908.574.200 / fax: 44.1908.574.300 ? asia/pacific tel: 81.44.844.8296 / fax: 81.44.844.8298 visit www.macom.com for additional data sheets and product information. v2 4 spurious table: 2100mhz (in dbc below if, assuming down conversion) nf lo - mf rf 0 x 9 17 22 30 1 35 0 37 57 45 rf 2 77 77 56 77 77 (n) 3 77 77 77 70 77 4 77 77 77 77 77 0 1 2 3 4 lo (m) rf = 2110 mhz, 0dbm lo = 2010 mhz, +13dbm if = 100 mhz spurious table: 2100mhz (in dbc below if, assuming down conversion) nf lo - mf rf 0 x 8 12 10 23 1 25 0 28 59 61 rf 2 77 77 62 52 77 (n) 3 77 77 77 77 70 4 77 77 77 77 77 0 1 2 3 4 lo (m) spurious table: 2170mhz (in dbc below if, assuming down conversion) nf lo - mf rf 0 x 10 13 22 32 1 33 0 45 59 47 rf 2 70 77 48 74 69 (n) 3 71 77 77 66 77 4 77 77 77 77 77 0 1 2 3 4 lo (m) rf = 2170 mhz, 0dbm lo = 2070 mhz, +13dbm if = 100 mhz spurious table: 2170mhz (in dbc below if, assuming down conversion) nf lo - mf rf 0 x 10 12 16 17 1 34 0 39 54 65 rf 2 73 77 65 60 77 (n) 3 77 77 77 77 77 4 77 77 77 77 77 0 1 2 3 4 lo (m) rf = 2170 mhz, 0dbm lo = 1670 mhz, +13dbm if = 500 mhz rf = 2100 mhz, 0dbm lo = 1610 mhz, +13dbm if = 500 mhz
|